News from 2024-10-16
Meinberg Security Advisory: [MBGSA-2024.06] LANTIME-Firmware V7.08.016
Meinberg recommends updating to LANTIME firmware version 7.08.016.
-
LANTIME-Firmware V7.08.015:
severity level critical(0), high (3), medium (2), low (0), info (0), unknown (0)
- LANTIME firmware: V7.08.016
-
Description of the Vulnerabilities
- Third-Party-Software:
- libexpat:
-
CVE-2024-45490 - xmlparse.c does not reject a negative length for XML_ParseBuffer (high)
CVE-2024-45491 - dtdCopy in xmlparse.c can have an integer overflow (high)
CVE-2024-45492 - nextScaffoldPart in xmlparse.c can have an integer overflow (high)
https://github.com/libexpat/libexpat/blob/R_2_6_3/expat/ChangesFixed in:
V7.08.016 MBGID-19238
-
- OpenSSL:
-
CVE-2024-6119 - Possible denial of service in X.509 name checks (medium)
https://openssl-library.org/news/vulnerabilities/index.htmlFixed in:
V7.08.016 MBGID-18972
-
- pam_radius:
-
CVE-2024-3596 - BlastRADIUS attack mitigations in pam_radius module (medium)
https://github.com/FreeRADIUS/pam_radius/releases/tag/release_3_0_0Fixed in:
V7.08.016 MBGID-18960 and MBGID-19103
-
- libexpat:
- Third-Party-Software:
-
Systems Affected
All LANTIME firmware versions before 7.08.016 are affected by the corresponding vulnerabilities. The LANTIME firmware is used by all devices of the LANTIME M series (M100, M150, M200, M250, M300, M320, M400, M450, M600, M900) as well as all devices of the LANTIME IMS series (M500, M1000, M1000S, M2000S, M3000, M3000S, M4000) and the SyncFire product family (SF1000, SF1100, SF1200, SF1500) and LANTIME CPU Expansions (LCES).
Whether and to what extent individual clients or LANTIME systems are vulnerable depends on the individual configuration, network infrastructure, and other factors, and it is therefore not possible to provide a general statement on how vulnerable a given system in use actually is.
-
Possible Security Measures
The relevant security updates are included in the LANTIME firmware versions 7.08.016(-light). Updating to these versions eliminates the listed vulnerabilities.
Download the latest LANTIME firmware at:
All updates are now available for Meinberg customers. An update of the LANTIME firmware to the version 7.08.016 respectively 7.08.016-light is recommended. Clients who cannot install version 7.08.016 should install version 7.08.016-light instead.
-
Further Information
Further details and information are available from the following website:
If you have any questions or need assistance, please, do not hesitate to contact Meinberg’s technical support team.
-
Acknowledgments
We would like to express our gratitude to all those who have advised us of vulnerabilities or other bugs, and have also suggested improvements to us.
Thank you!
![[Preview]Meinberg Security Advisory: [MBGSA-2024.06] LANTIME-Firmware V7.08.016 - Meinberg News](/css/buttons/xde.png.pagespeed.ic.STRk-ATSUv.png)